Steam Generator Inspection
INETEC provides eddy current and ultrasonic pre-service and in-service inspection of PWR and VVER steam generators with its own highly sophisticated equipment. INETEC has experienced service personnel and state-of-the-art equipment to efficiently inspect all VVER 440/1000 and PWR type steam generator tubing.
Inspection of steam generator includes:
- Eddy current inspection of the tubes using standard bobbin probes and array probes
- Eddy current inspection of the VVER 1000 steam generator collector material using standard rotating probes and array probes
- Ultrasonic inspection of the steam generator collector welds
- Ultrasonic inspection of the steam generator tubes
- Eddy current inspection of the primary flange threaded holes
- Eddy current inspection of the secondary flange threaded holes.